LINSHANG - Coating Thickness Gauge LS225
LINSHANG - Coating Thickness Gauge LS225 Color & Paint Coating Measurement Melaka, Malaysia, Ayer Keroh Supplier, Suppliers, Supply, Supplies | Carlssoon Technologies (Malaysia) Sdn Bhd
Download Files
1_LS225.pdf (375.75 KB)
LINSHANG - Coating Thickness Gauge
Brand: Linshang
Model: LS225



Features:
* Accuracy: +/-(2%+0.3um)
* Suitable for coating thickness which lower than 10micron
Measure the anodic oxide layer thickness on aluminum N1500


Machine Introduction:
Coating thickness gauge is composed of the host and the probe. The host is mainly used for the display and statistics of measurement data. The probe uses digital technology, the data collection and processing is completed on the probe. According to the different substrates, one ferrous probe (F500) and one non ferrous probe (N1500) have been developed.



Technical Specifications:
Display 240×160 dot matrix LCD
Power supply 4pcs of 1.5V AAA alkaline battery
Operation temperature range 0C-50C
Storage temperature range -20C-60C
Host size 148*76*26 mm
Weight(with battery) 194g


F500 Probe Technical Parameter:
Parameter Value
Measuring principle Magnetic Induction
Measuring range 0.0-500μm
Resolution 0.1μm: 0μm - 99.9μm
1μm: 100μm - 500μm
Repeatability ≤ ± (0.8%H+0.1μm) Test with fixture, H is the standard value
Accuracy ≤±(2%H+0.3μm) after calibration of 1-5 points, H is the standard value
Unit μm / mil
Measuring interval 1.5s
Minimum measuring area Ø = 7mm
Minimum curvature Convex:1.5mm / Concave:10mm
Minimum substrate thickness 0.1mm
Calibration Support zero reference adjustment and 1 to 5-points calibration
Probe size 110*15 mm (Without connecting cable)
Probe weight 81g
 

N1500 Non-Ferrous Probe Technical Parameters:

Parameter Value
Measuring principle Eddy current
Substrate Non-ferromagnetic metal
Measuring range 0.0-1500μm
Resolution 0.1μm: 0μm - 99.9μm
1μm: 100μm - 999μm
0.01mm: 1.00mm – 1.50mm
Repeatability ≤ ± (0.8%H+0.1μm) Test with fixture, H is the standard value
Accuracy ≤±(2%H+0.3μm) after 5 points calibration, H is the standard value
Unit μm / mil
Measuring interval 0.8s
Minimum measuring area Ø = 7mm
Minimum curvature Convex:1.5mm / Concave:10mm
Minimum substrate thickness 0.05mm
Calibration Support zero reference adjustment and 1 to 5-points calibration
Probe size 110*15 mm (Without connecting cable)
Probe weight 81g
 

 

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version