383 / 427
Fluke - 87V Industrial Multimeter
Fluke - 87V Industrial Multimeter Others Melaka, Malaysia, Ayer Keroh Supplier, Suppliers, Supply, Supplies | Carlssoon Technologies (Malaysia) Sdn Bhd
Download Files
Fluke_87V_Industrial_Multimeter.PDF (116.34 KB)
Fluke - 87V Industrial Multimeter
Brand : Fluke
Model : 87V

 

The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment - even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.
 
  • Easy-access door for fast battery changes without breaking the calibration seal
  • Analog bar graph for fast changing or unstable signals
  • Large digit display with bright, two-level backlight for easier reading in low light
  • Touch Hold keeps readings on display even after removing probes
 
The 87V lets you identify complex electrical problems fast. It supports accurate measurements on VFDs using a low-pass filter. The meter also captures intermittent as fast as 250 µS using Peak Capture. High-frequency, high-energy noise generated by large drive systems is blocked from your measurements with specially designed shielding.
 
Features
 
  • Identify complex signal problems fast
  • Supports accurate measurements on VFDs using a low-pass filter
  • Captures intermittent as fast as 250 µS with Peak Capture
 
Specifications
 
Specifications
Voltage DC Maximum voltage 1000 V
Accuracy ±(0.05% + 1)
Maximum resolution 10 µV
Voltage AC Maximum voltage 1000 V
Accuracy ±(0.7% + 2) True RMS
AC bandwidth 20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution 0.1 mV
Current DC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(0.2% + 2)
Maximum resolution 0.01 µA
Current AC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(1.0% + 2) True RMS
Maximum resolution 0.1 µA
Resistance Maximum resistance 50 MΩ
Accuracy ±(0.2% + 1)
Maximum resolution 0.1 Ω
Capacitance Maximum capacitance 9,999 µF
accuracy ±(1% + 2)
Maximum resolution 0.01 nF
Frequency Maximum frequency 200 kHz
Accuracy ±(0.005% + 1)
Maximum resolution 0.01 Hz
Duty cycle Maximum duty cycle 99.9%
Accuracy ±(0.2% per kHz + 0.1%)
Maximum resolution 0.1%
Temperature measurement –200.0 °C – 1090 °C
–328.0 °F – 1994.0 °F
excluding probe
80 BK temperature probe –40.0 °C – 260 °C
–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
Conductance Maximum conductance 60.00 nS
Accuracy ±(1.0% + 10)
Maximum resolution 0.01 nS
Diode Range 3 V
Resolution 1 mV
Accuracy ±(2% + 1)
Duty cycle range Accuracy Within ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature –20 °C to + 55 °C
Storage temperature –40 °C to + 60 °C
Humidity (without condensation) 0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category EN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvals CE, CSA, RCM
Mechanical and General Specifications
Size 201 x 98 x 52 mm (with holster)
Weight 355 g
624 g – with holster
Display Digital 6000 counts updates 4/sec.
19,999 counts in high–resolution mode
Analog 32 segments, updates 40/sec
Frequency 19,999 counts, updates 3/sec at > 10 Hz
Warranty Lifetime
Battery Life Alkaline ~400 hours typical, without backlight
Shock 1 Meter drop per IEC 61010–1:2001
Vibration Per MIL–PRF–28800 for a Class 2 instrument