LUTRON - Mini Vane Type Anemometer AM4233SD
LUTRON - Mini Vane Type Anemometer AM4233SD Pressure & Flow Melaka, Malaysia, Ayer Keroh Supplier, Suppliers, Supply, Supplies | Carlssoon Technologies (Malaysia) Sdn Bhd
3 Measurement FunctionSetting Guide

 LUTRON - Mini Vane Type Anemometer
Brand: Lutron
Model: AM4233SD

# Minimun Telescopic Probe Length: 280mm



Product Introduction:
Lutron AM-4233SD is an anemometer with external probe, that can measure gas flow rate in range 0,4 - 20,0 m/s and temperature in range 0 - 50 °C.
 
Features:

  • Mini vane with 35mm Dia., lowfriction ball bearing mounted wheel design provides high accuracy at high and low air velocity.
  • Telescope probe, extension length 620 mm max.
  • Replacement anemometer van set.
  • Air velocity : m/s, Ft/min, Km/h, Knot, Mile/h,
  • Air flow ( CFM, CMM ) measurement.
  • Air temperature ( ¡æ¨H)
  • Air Temp. used thermistor sensor, fast response time.
  • Fast humidity measuring response time.
  • Type K, Type J thermocouple thermometer.
  • Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder, sampling time set from 1 second to 3600 seconds.
  • Manual datalogger is available (set the sampling time to 0 ), during execute the manual datalogger function, it can set the different position ( location ) No.  (position 1 to position 99 ).
  • Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer, it can down load the all the measured value with the time information ( year/month/date/ hour/minute/second ) to the Excel directly, then user can make the further data or graphic analysis by themselves.
  • SD card capacity : 1 GB to 16 GB.
  • LCD with green light backlight, easy reading.
  • Can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Microcomputer circuit, high accuracy.
  • Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.
  • Separate probe, easy for operation.
  • Applications : Environmental testing,  HVAC, Air conveyors, Flow hoods, Clean rooms, Air velocity, Air balancing, Fans/motors/blowers, Furnace velocity, Refrigerated case, Paint spray booths . measurements.
 
Technical Specification:

Circuit Custom one-chip of microprocessor LSI circuit.
Display LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).
Measurement Air velocity:
Unit m/s (meters per second) Km/h ( kilometers per hour )
Ft/min ( FPM, feet per minute )
Knots ( nautical miles per hour )
Mile/h ( mph, miles per hour )
Air flow :
CFM, CMM

  • CFM : cube feet per minute
  • CFM : cube meters per minute
Type K/ Type J thermometer :¡æ¨H,
Air temperature: ¡æ¨H,
Datalogger Auto 1 second to 3600 seconds
Sampling Time @Sampling time can set to 1 second,  but memory data  may loss.
Setting range Manual Push the data logger button once will save data one time.
@Set the sampling time to 0 second.
@Manual mode, can also select the 1 to 99 position ( Location ) no.
Memory Card SD memory card. 1 GB to 16 GB.
 *It recommend use memory card ¨Q 4 GB.
Advanced  *Set clock time ( Year/Month/Date,
setting Hour/Minute/ Second )
 *Set sampling time
 *Auto power OFF management
 *Set beep Sound ON/OFF
 *Decimal point of SD card setting
 *SD memory card Format
 *Set thermometer type to Type K or Type J
 *Set temperature unit to  ¡æ ¨H or      
 * Set air flow type ( CFM/USA, CMM/EURO )  * Set air flow area dimension
Temperature Automatic temp. compensation for the
Compensation type K/J thermometer.
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time of Display Approx. 1 second.
Operating
Temperature
to 50 ¡æ
 
 
 













































ELECTRICAL SPECIFICATIONS  (23±5 ¡æ)
 

Measurement   Range Resolution Accuracy
    m/s 0.2 to 5.0 m/s  0.01 m/s ± ( 5% + a )
  5.1 to 20.0 m/s  0.1 m/s reading    
    Km/h         0.70 to 18.00 km/h  0.01 Km/h  
  18.0 to 72.0 km/h  0.1 Km/h     or
± ( 1% + a )
    Mile/h         0.50 to 11.20 mph  0.01 mph
 (MPH ) 11.2 to 44.7 mph  0.1 mph full scale
    Knot 0.40 to 9.70 knot  0.01 Knot
  9.7 to 38.8 knot  0.1 Knot  
    Ft/min        40-3940 ft/min Ft/min  
@ a = 0.1 m/s, 0.3 km/h, 0.2 mile/h, 0.2 knot, 20 ft/min
Note: 
m/s - meters per second          km/h - kilometers per hour       
ft/min - feet per minute            knot - nautical miles per hour
mile/h - miles per hour            (INTERNATIONAL KNOT)




















Air Temperature:
Measuring Range ¡æ ¡æ ¨H to 50 /32        to 122 ¨H
Resolution 0.1 ¡æ ¨H/0.1
Accuracy ± 0.8 ¡æ ¨H/1.5



 

Air Flow:

Measurement Range Resolution
CMM ( m^3/min. ) to 54,000 CMM  0.001 to 1 CMM
CFM ( ft^3/min. ) to 1,907,000 CFM  0.001 to 100 CFM





Measurement Area
CMM ( m^3/min. )  0.001 to 30.000 m^2
CFM ( ft^3/min. )  0.01 to 322.93 ft^2

 
 
 


Type K/J Thermometer:

Sensor Type Resolution Range Accuracy
Type K 0.1 ¡æ -50.0 to 1300.0 ¡æ ± ( 0.4 % + 0.5 ¡æ )
-50.1 to -100.0 ¡æ ± ( 0.4 % + 1 ¡æ )
0.1 ¨H -58.0 to 2372.0 ¨H ± ( 0.4 % + 1 ¨H )
-58.1 to -148.0 ¨H ± ( 0.4 % + 1.8 ¨H )
Type J 0.1 ¡æ -50.0 to 1200.0 ¡æ ± ( 0.4 % + 0.5 ¡æ )
-50.1 to -100.0 ¡æ ± ( 0.4 % + 1 ¡æ )
0.1 ¨H -58.0 to 2192.0 ¨H ± ( 0.4 % + 1 ¨H )
-58.1 to -148.0 ¨H ± ( 0.4 % + 1.8 ¨H )

















Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version